Firmware AC 1.3-1.22667 - Avoids the Proportional part of the last scan's output when the external loop is disabled. 1.3-1.22193 - Fixed Heat Sheet Chemical accountg, take the last values reported just before EOH. BugzID: 2955 - Fixed ShadowModePwrOnPercent to be calculated at the heat level too, not only in subreports BugzID: 2957 - Fixed ShadowModePwrOnPercent to be reported as percentage, not fraction - ShadowMode disables the ManualOperation alarm - ShadowMode prevents the furnace switch from triping - Added HeatSheet.ShadowModePwrOnPercent, percentage of time that the PX3 ran in Shadow mode - Removed spurious Bounce fields 1.3-1.22163 - Balance integral is calculated per phase and per shell 1.3-1.22153 - Fixed End of Charge handling when SA is not active. 1.3-1.21252 - Fixed Model handling problem that may not import correctly form a DB - Added Vibration alarm, event and heat report counters - Invalid charge diangostic message is now only reported when changing (avoid spam for charge 0) - Fixed External Loop Disabled alarm that was reported with all phases in Manual - NCC decides FCE ON by using Voltage or Current (instead of Vacuum Switch) - Fixed NCC to avoid a permanent NCC when the Band is greater than the Dynamic NCC Offset 1.3-1.20821 - Regulation ramps are always active, special states affect only the accelerating ramp on the corresponding direction. 1.3.19315 - Frequency changed alarm was incorrectly disabled - Transformer Ratio alarm was not working - Invalid tap numbers are now ignored (instead of clamped), it uses last valid value - Average Error for Ext Loop Max Error % is now squared and sqrt’d to avoid sign problems - Dynamic NCC algorithm changed to account for Top and AutoLower logic - New External Loop Disabled alarm (reports when ExtLoop is disabled for 60s) - Balance uses same permissives as External Loop - Substation tap changer end of life message was incorrectly generated - Charge 1 reports AvgMW equal to ChargeMW - For Z and R only regulation modes, I-Z/R Max Error % is used (Willie) - R regulator clamps SP to >R_sc - Fixed AdvancedControl configuration, it did not save changes properly - ShadowMode bit is logged 1.3.18800 - Fixed Frequency changed alarm, it was not working in all previous 1.3 versions BugzID: 2788 1.3.18684 - Bit renamed to Operation.ShadowMode 1.3.18658 - Fixed ChargeAvgMW calculation to match HeatAvgMW in first charge BugzID: 2761 - Fixed ExtLoop disable average error calculation (now uses sqrt(Average of Error^2)) BugzID: 2753 1.3.18590 - InvalidTapCombination alarm could fire incorrectly until the actual tap value changed. BugzID: 2760 1.3.18564 - Fixed Logger problem. CaveInStatus and OperationShell2 were swapped. BugzID: 2756 - Dynamic NCC underscore (_) removed from name. BugzID: 2756 - Transient Counters on IOAccumulators changed to unsigned. Merged from trunk up to Rev. 18554 - Published Dynamic NCC Setpoint BugzID: 2756 - Fixed Spillover overload setpoint default from 100 to 0 BugzID: 2741